Alkaline Water Electrolysis PEM Water Electrolysis HRS

Hela 1000/2000 Series


This series of alkaline water electrolysis hydrogen production equipment, consisting of a newly developed electrolytic cell and a newly designed BOP system, has the advantages of low energy consumption, small size and high stability. The electrolyzer material is replaced by a new and stable material for the electrode plate, which not only reduces energy consumption, but also solves the problems of the traditional electrolyzer reaching its length limit, weight limit and frequent engineering problems.


Advantage
1
Low energy consumption
The voltage of the conventional electrolyzer is 2V, and the current density is 3000A/㎡, while the new electrolyzer HELA2000/HELA2000Plus can reach the current density of 4300A/㎡ under the voltage of 1.92V in the small chamber. Therefore, electricity consumption is reduced compared to conventional electrolyzers. The DC power consumption of the 2000Nm³/h Hygreen electrolyzer is less than 4.6kW h/Nm³H2, and the minimum of Plus is 4.2-4.4kW·h/Nm³H2, which is 2.13% lower than the DC power consumption of the conventional electrolyzer (4.7kW·h/Nm³H2), and the highest reduction is 6.38% or more.
2
Wide load
The new type of electrolyzer adopted has a maximum adjustable range of 110%. The new Hygreen electrolyzer has a current density of 4300A/㎡ under the voltage of 1.92V in the small chamber, and a current density of 6000 A/㎡ under the voltage of 2V in the small chamber. It is more adaptable to the high volatility of renewable energy and provides a more economical solution and possibility for a more reasonable allocation of hydrogen generation from photovoltaic wind power.
3
Boot speed
Improved the control method and shortened the start-up time. The volume of the electrolytic cell is greatly reduced by increasing the current density, which is beneficial to the temperature rise and temperature control of the electrolytic cell. Greatly reduces electrolyzer full load state. PART 04 Advantages of HELA2000/HELA2000Plus
2
Small size and highly economical
The change of materials also greatly reduces the weight of the electrolyzer, which is reduced to about 70% of the weight of the original electrolyzer. Greatly reduces engineering problems during assembly, transportation, installation, commissioning, operation and maintenance. The cost of transportation, installation, commissioning, operation and after-sales maintenance is reduced. Low power consumption and wide load greatly reduce the operating costs of the project, improve the matching degree of power generation and hydrogen generation, and thus increase the return on investment of the overall green hydrogen project.
5
High performance
The new electrolyzer structure has greatly improved the purity problem in the traditional diaphragm, and improved the purity of the hydrogen/oxygen. The purity of oxygen before purification is increased to over 98.5%. The purity of the hydrogen produced by the electrolyzer is above 99.8.
6
Life Span,Stability and Safety
The electrolytic cell adopts a flat plate, which avoids the disadvantage of the diaphragm being damaged as the usage time increase in the conventional electrolytic cell, which was caused by the difference in the plate stamping nipple, thus ensuring the life span, stability and safety of the electrolytic cell.
Parameter

HELA1000

HELA2000

HELA2000 +

Electrolysis Technology

Alkaline

Alkaline

Alkaline

Stack Power

5MW

10MW

10MW

System Efficiency

80%

77%

80%

Output Pressure

1.6MPa

1.6MPa

1.6MPa

    Start-up Time
   (from stand-by)

40-60min

40-60min

40-60min

15min

15min

15min

Water Consumption

900L/h

1,800L/h

1,800L/h

Stack Design Life

80,000h

80,000h

80,000h

Hydrogen Gas Production

1,000N/h

2,000N/h

2,000N/h

Oxygen Gas Production

500N/h

1,000N/h

1,000N/h

Current Density

3,000A/㎡

4,500A/

8,000A/

Voltage of Single Cell

1.84V

1.92V

1.84V

DC Power Consumption

4.4kWh/Nm³ H₂

4.6kWh/N H₂

4.4kWh/N H₂

Operating Range

30%-110%

30%-110%

30%-110%

Hydrogen Purity at Outlet

99.80%

99.80%

99.80%

Oxygen Purity at Outlet

98.50%

98.50%

98.50%

Operating Temperature

90±5

90±5